H Pylori Antibody Subtype Stomach Cancer Screening Blood Test Kit

  • H Pylori Antibody Subtype Stomach Cancer Screening Blood Test Kit
H Pylori Antibody Subtype Stomach Cancer Screening Blood Test Kit
  • Wizbiotech
  • CE,UKCA
  • China

This kit is applicable to in vitro qualitative detection of Urease antibody, CagA antibody and VacA antibody to helicobacter pylori in human whole blood, serum or plasma sample, and it's suitable for auxiliary diagnosis of HP infection as well as identification of type of helicobacter pylori patient infected with.

Description

Helicobacter pylori can be divided into two types based on expression of CagA and VacA: type I is toxigenic strain (with expression of both CagA and VacA or any one of them), which's highly pathogenic and easy to cause gastric diseases; type II is atoxigenic HP (without expression of both CagA and VacA), which’s less toxic and normally doesn't have clinical symptom upon infection.


Benefits

  • Diagnostic valueThe H. pylori antibody test helps healthcare providers to dignose which type of hp the patient infected. It provides important information for clinical decision-making, including treatment and management options.

  • Convenient: The H. pylori antibody subtype test only requires a single blood sample and is easy to perform, making it a convenient option for both patients and healthcare providers.


Product Specifications

Method

Fluorescence Immunochromatographic Assay

Sample Type

Whole blood/Serum/Plasma
Time to Result15mins
Storage

2~30 ℃/36~86℉

Shelf Life24 months from date of manufacture

Kit Size

1/5/20/25 tests

※ Refer to Package Insert for additional product information.


Product Performance


WIZ Results of 

Urease antibody

Test result of Reference reagent

Positive coincidence rate:

94.39% (95%C.I. 90.46%~96.76%)


Negative coincidence rate:

99.32% (95%C.I. 96.28%~99.88%) 


Total coincidence rate: 

96.41% (95%C.I. 93.95%~97.89%)

PositiveNegativeTotal 
Positive2021203
Negative12147159
Total 214148362


WIZ Results of 

CagA antibody

Test result of Reference reagent

Positive coincidence rate:

95.28% (95%C.I. 89.43%~97.97%) 


Negative coincidence rate:

97.66% (95%C.I. 94.98%~98.92%) 


Total coincidence rate: 

96.96% (95%C.I. 94. 64%~98.29%)

PositiveNegativeTotal 
Positive1016
107
Negative5250255
Total 106256362


WIZ Results of 

   VacA antibody

Test result of Reference reagent

Positive coincidence rate: 

94.23% (95%C.I. 87.98%~97.33%) 


Negative coincidence rate: 

97.29% (95%C.I. 94.51%~98.68%) 


Total coincidence rate: 96.41% 

(95%C.I. 93.95%~97.89%)

PositiveNegativeTotal 
Positive987105
Negative6251257
Total 104258362


Applications

  • Outpatient Emergency Laboratory

  • Clinical Departments

  • Community Hospital

  • Laboratory Departments

  • Health Management Center

  • Clinic


Certifications