Colon Cancer Calprotectin Fecal Occult Blood Fit Combo Test
- Wizbiotech
- CE, MDA
- China
This kit is used for qualitative detection of calprotectin and hemoglobin in human stool sample.It only takes 10~15 minutes to get results, which enables healthcare providers to diagnose diagnosis of inflammatory bowel disease and gastrointestinal bleeding earlier allowing individuals to seek medical care sooner.
Description
Calprotectin and fecal occult blood are two important diagnostic tests used in the evaluation of gastrointestinal disorders. These tests are non-invasive and easy to perform, making them a popular choice for patients and physicians alike.
Calprotectin is a protein found in the neutrophils of the human body. It is released when there is inflammation in the gut, making it a useful marker for inflammatory bowel disease (IBD) and other gastrointestinal disorders.
Fecal occult blood, on the other hand, is a test used to detect the presence of blood in the stool. Blood in the stool can be a sign of several gastrointestinal conditions, including hemorrhoids, ulcerative colitis, and colorectal cancer.
Benefits
Very simple to use: The calprotectin and fobt combo test takes stool as sample, you only need 3 steps to get the result.
Quick result: The calprotectin and fecal occult blood test provides result in 10 minutes.
Convenient: The combo test kit provides sample collection tube, you don't need additional tool to perform the test.
Product Specifications
Method | Colloidal Gold |
Sample Type | Faeces |
Time to Result | 10~15mins |
Storage | 2~30 ℃/36~86℉ |
Shelf Life | 24 months from date of manufacture |
Kit Size | 1/5/20/25 tests |
※ Refer to Package Insert for additional product information.
Product Performance
WIZ Results of Cal | Test result of Reference reagent | Positive coincidence rate: 99.40% (95%C.I. 96.69%~99.89%) Negative coincidence rate: 100.00% (95%C.I. 97.64%~100.00%) Total coincidence rate: 99.69% (95%C.I. 98.28%~99.95%) | ||
Positive | Negative | Total | ||
Positive | 166 | 0 | 166 | |
Negative | 1 | 159 | 160 | |
Total | 167 | 159 | 326 |
WIZ Results of FOB | Test result of Reference reagent | Positive coincidence rate: 99.44% (95%C.I. 96.92%~99.90%) Negative coincidence rate: 100.00% (95%C.I. 97.44%~100.00%) Total coincidence rate: 99.69% (95%C.I. 98.28%~99.95%) | ||
Positive | Negative | Total | ||
Positive | 179 | 0 | 179 | |
Negative | 1 | 146 | 147 | |
Total | 180 | 146 | 326 |
Applications
Outpatient Emergency Laboratory
Clinical Departments
Community Hospital
Laboratory Departments
Health Management Center
Clinic
Certifications