Fecal Occult Blood FOB Fit Colon Cancer Bowel Cancer Screening Test Kit Visual Result

  • Fecal Occult Blood FOB Fit Colon Cancer Bowel Cancer Screening Test Kit Visual Result
  • Fecal Occult Blood FOB Fit Colon Cancer Bowel Cancer Screening Test Kit Visual Result
  • Fecal Occult Blood FOB Fit Colon Cancer Bowel Cancer Screening Test Kit Visual Result
Fecal Occult Blood FOB Fit Colon Cancer Bowel Cancer Screening Test Kit Visual Result
  • Wizbiotech
  • CE,UKCA
  • China

This kit is used for qualitative detection of hemoglobin in human stool sample.It only takes 10~15 minutes to get results,which enables healthcare providers to evaluate of gastrointestinal bleeding earlier allowing individuals to seek medical care sooner.

Description

A stool occult blood test is used to check for the presence of blood in the stool that is not visible to the naked eye. The fobt test is usually done as a screening test for colon cancer or other gastrointestinal disorders that can cause bleeding in the digestive tract. The test is also used to monitor the effectiveness of treatment for gastrointestinal conditions or to detect the recurrence of cancer after treatment. It is recommended for people over the age of 40 or for those with a family history of colon cancer or other gastrointestinal disorders.


Benefits

  • Screening value: Colonrectal cancer is a potential risk for people especially those elder than 40. The fobt test can help people understand the risk of colon cancer or other gastrointestinal disorders.

  • Stable: The fecal occult blood test is a immunology test. Compare to guaiac test, the fobt test result won't be impacted by food or drug.

  • Convenient: The fobt test kit provides stool sample collection tube, which helps patient collecting sample.


Product Specifications

Method

Colloidal Gold

Sample Type

Faeces

Time to Result

10~15mins

Storage

2~30 /36~86

Shelf Life

24 months from date of manufacture

Kit Size

1/5/20/25 tests

※ Refer to Package Insert for additional product information.


Product Performance


WIZ Results

Test result of Reference reagent

Positive coincidence rate:

99.33% (95%C.I. 96.32%~99.88%)


Negative coincidence rate: 

100.00% (95%C.I.97.29%~100.00%) 


Total coincidence rate: 

99.65% (95%C.I.98.06%~99.94%)

PositiveNegativeTotal
Positive1490149
Negative1138139
Total150138288