Our stool transferrin test is used to detect gastrointestinal bleeding, particularly in patients who have chronic gastrointestinal bleeding or who have a family history of gastrointestinal cancer.
This transferrin test measures the level of transferrin, a protein that binds to iron, in the stool. If the level of transferrin in the stool is high, it may indicate that there is bleeding in the gastrointestinal tract.

Intended Use

The transferrin kit is suitable for in vitro qualitative detection of transferrin (Tf) in human fecal samples for the auxiliary diagnosis of gastrointestinal bleeding. This kit only provides test results for transferrin (Tf) levels, and the obtained results should be analyzed in combination with other clinical information. It must only be used by healthcare professionals.


Benefits

  • Very simple to use: The tansferrin test takes stool as sample, healthcare providers don't need an additional complex training to perform the test.

  • Quick result: The tf test kit can provide you the result in 10 minutes.

  • Convenient: The tf test kit provides stool sample collection tube, you don't need to worry about sample processing.

  • Diagnostic ValueThe stool transferrin test is particularly useful in detecting small amounts of bleeding that may not be visible to the naked eye. It provides information that is essential for diagnosis and treatment decision making.


Product Specifications

Method

Colloidal Gold

Sample Type

Faeces

Time to Result

10~15mins

Storage

2~30 /36~86

Shelf Life

24 months from date of manufacture

Kit Size

1/5/20/25 tests

※ Refer to Package Insert for additional product information.


Product Performance


WIZ Results

Test result of Reference reagent

Positive coincidence rate:

99.45% (95%C.I. 96.94%~99.90%) 


Negative coincidence rate: 99.15% (95%C.I.95.32%~99.85%) 


Total coincidence rate: 99.33% (95%C.I.97.59%~99.82%)

PositiveNegative Total
Positive 1801181
Negative 1116117
Total181117298